Single Beam UV Visible Spectrophotometer BHV1C3

Spectrophotometer
  • Sea, Air, Door to Door Shipping
  • 1 Year Warranty
  • US & European Standards



Single Beam UV Visible Spectrophotometer 190-1100 nm 4 nm

Specifications

ModelBHV1C3
Wavelength Range190-1100 nm
Spectral Bandwidth4 nm
Optical SystemSingle Beam, Grating 1200 lines/mm
Wavelength Accuracy±0.5 nm
Wavelength Repeatability0.3 nm
Photometric Accuracy±0.5%T or ±0.004A @ 1A
Photometric Range0-200%T,-0.3-3 A, 0-9999 Conc
Stray Light0.05%T @ 220 nm, 360 nm
Stability±0.001 A/h @ 500 nm
DisplayGraphic LCD (128*64 dots)
Keyboard22 Membrane keypad
Standard Cell HolderStandard 10 mm pathlength cuvette
Sample Compartment4-position 10 mm cell changer
Light SourceTungsten & Deuterium lamp
OutputUSB Port & Parallel Port (Printer)
Power RequirementAC 110/220 V 50/60 Hz
Dimensions (LxWxH)470x373x187 mm
Weight14 kg

Description

Simple-to-use instruments with advanced performance, its stray light is only 0.05%T. The local stand-alone software provides functions of Photometry, Quantitative Test, Kinetics and System Utilities functions.

Features

Large LCD screen (128*64 Dots).
The system can also save the test results, a total of 200 groups of data and 200 standard curves can be saved in the RAM. Convenient for check and reload.
Data can be restored after a sudden power cut.
Auto setting wavelength.
Tungsten lamp & Deuterium lamp can be turned on/off individually to extend lifetime.
The optional application software M. Wave Professional provides complete control of the spectrophotometer from a computer through the built-in USB port. It can expand to the following functions: Quantitative, Kinetics, Wavelength Scan, Multi-wavelength & DNA/Protein Test.
Pre-aligned design makes it convenient to change lamps.
Large sample compartment; it can accommodate 5-100 mm path length cuvettes with optional holders. A variety of optional accessories are available.


Main Menu:
Move the cursor on the function menu you want, then press ENTER key to go into the corresponding interface.
Large LCD screen (128*64 Dots). The system can also save the test results, a total of 200 groups of data and 200 standard

Basic Mode:
Absorbance, Transmittance or Concentration measurements.
It can display and save 200 groups of data, 5 groups per screen.
Basic Mode: Absorbance, Transmittance or Concentration measurements. It can display and save 200 groups of data, 5 groups

Kinetics:
This mode may be used for time course scanning or reaction rate calculations. Abs. VS Time graphs are displayed on the screen in real time. It can record 1000 data.
Kinetics: This mode may be used for time course scanning or reaction rate calculations. Abs. VS Time graphs are displayed on

Quantitative:
Standard Curve
At most, 9 standard samples can be used to establish a standard curve. The curve and its equation will be displayed on the screen simultaneously. You can measure your unknown concentration solutions by the curve. Total 200 curves can be saved in the RAM.
Coefficient Method
If you have known the coefficient K*a + b is known, you can input them directly by the button, and then test your unknown solutions.
Quantitative: Standard Curve At most, 9 standard samples can be used to establish a standard curve. The curve and its

System Utilities:
Lamp management, time & date set, obtain dark current, calibrate wavelength, default system, and some other system functions.
System Utilities: Lamp management, time & date set, obtain dark current, calibrate wavelength, default system, and some


M. Wave Professional PC-Control Software:

Brief Introduction:
M. Wave Professional application software is based Microsoft Windows, the instrument can be controlled by PC software through the built-in USB communication port, which makes the UV/Vis Series with more functions and easy to control.

Quantitative:
Use up to 20 standards to establish a standard curve. Three methods for fitting a curve:
Linear fit.
Linear through zero.
Square fit.
Quantitative: Use up to 20 standards to establish a standard curve. Three methods for fitting a curve: Linear fit. Linear

Multi-wavelength Test:
You can set up to 20 wavelengths to measure a sample.
Multi-wavelength Test: You can set up to 20 wavelengths to measure a sample. Single Beam UV Visible Spectrophotometer

Wavelength Scan:
Automatically records peaks and valleys.
The quantity of the curves stored is unlimited.
Post-run manipulation and processing includes:
Re-scaling axes, curve.
Smoothing, combination, zooming, overlap.1 to 4 derivatives.
Wavelength Scan: Automatically records peaks and valleys. The quantity of the curves stored is unlimited. Post-run

Kinetics:
The Kinetics mode may be used for scanning time courses or reacting rate calculations. Abs. Vs. Time graphs are displayed.
Kinetics: The Kinetics mode may be used for scanning time courses or reacting rate calculations. Abs. Vs. Time graphs are

DNA/Protein Test:
Optional two formulas:
DNA Concentration = 62.9A260 - 36.0A280 or 49.1A260 - 75.8A230
You can also enter other wavelengths and factors to calculate.
DNA/Protein Test: Optional two formulas: DNA Concentration = 62.9A260 - 36.0A280 or 49.1A260 - 75.8A230 You can also enter
Functions:
Photometry
Absorbance, Transmittance or Energy measurements. It can display and save 200 groups of data, 5 groups per screen.
Quantitative
Standard Curve
At most, 9 standard samples can be used to establish a standard curve. The curve and its equation will be displayed on the screen simultaneously. You can measure your unknown concentration solutions by the curve.
A total of 200 curves can be saved in the Memory.
Coefficient Method
If the coefficient k & b in the formula C = k*a + b is known, you can input them directly by the button, and then test your unknown solutions.
Kinetics
This mode may be used for time course scanning or reaction rate calculations. Abs. VS Time graphs are displayed on the screen in real time. It can record 1000 data.
System Utilities
Lamp management, time & date set, obtain dark current, calibrate wavelength, default system, and some other system functions.

Accessories For Purchase

imagesnameog_model
imagesnameog_modelog_pricepriceMicro Cell Holder(Beam height: 15mm)9002408-Position Auto Cell Changer9003104-Cell Holder for
Micro Cell Holder
(Beam height: 15mm)
900240
imagesnameog_modelog_pricepriceMicro Cell Holder(Beam height: 15mm)9002408-Position Auto Cell Changer9003104-Cell Holder for
8-Position Auto Cell Changer
900310
imagesnameog_modelog_pricepriceMicro Cell Holder(Beam height: 15mm)9002408-Position Auto Cell Changer9003104-Cell Holder for
4-Cell Holder for 10mm SQU.cuvette
900410
imagesnameog_modelog_pricepriceMicro Cell Holder(Beam height: 15mm)9002408-Position Auto Cell Changer9003104-Cell Holder for
4-Cell Holder for 50mm SQU.cuvette
900420
imagesnameog_modelog_pricepriceMicro Cell Holder(Beam height: 15mm)9002408-Position Auto Cell Changer9003104-Cell Holder for
4-Cell Holder for 100mm SQU.cuvette
900430
imagesnameog_modelog_pricepriceMicro Cell Holder(Beam height: 15mm)9002408-Position Auto Cell Changer9003104-Cell Holder for
Square Cuvettes
Glass :10 mm
916101
QUARTZ: 10 mm 916111
20 mm 916112 30 mm 916113
50 mm 916114 100 mm 916115
20 mm
916102
30 mm
916103
50 mm
916104
100 mm
916105
Square cuvettes Quartz:10 mm
916111
20 mm
916112
30 mm
916113
50 mm
916114
100 mm
916115
imagesnameog_modelog_pricepriceMicro Cell Holder(Beam height: 15mm)9002408-Position Auto Cell Changer9003104-Cell Holder for
Micro cell, Quartz
(Beam height: 15mm)
100UL
916126
200UL
916127
500UL
916123
imagesnameog_modelog_pricepriceMicro Cell Holder(Beam height: 15mm)9002408-Position Auto Cell Changer9003104-Cell Holder for
Sipper System
900140
imagesnameog_modelog_pricepriceMicro Cell Holder(Beam height: 15mm)9002408-Position Auto Cell Changer9003104-Cell Holder for
Constant-Temperature System
900150
imagesnameog_modelog_pricepriceMicro Cell Holder(Beam height: 15mm)9002408-Position Auto Cell Changer9003104-Cell Holder for
Constant-Temperature Sipper System
900160
imagesnameog_modelog_pricepriceMicro Cell Holder(Beam height: 15mm)9002408-Position Auto Cell Changer9003104-Cell Holder for
Test Tube Holder
900530
imagesnameog_modelog_pricepriceMicro Cell Holder(Beam height: 15mm)9002408-Position Auto Cell Changer9003104-Cell Holder for
Cylindrical Cell Holder
900540
imagesnameog_modelog_pricepriceMicro Cell Holder(Beam height: 15mm)9002408-Position Auto Cell Changer9003104-Cell Holder for
Solid Sample Holder (Single Cell)
900550
imagesnameog_modelog_pricepriceMicro Cell Holder(Beam height: 15mm)9002408-Position Auto Cell Changer9003104-Cell Holder for
Water-Jacketed Cell Holder
900610
imagesnameog_modelog_pricepriceMicro Cell Holder(Beam height: 15mm)9002408-Position Auto Cell Changer9003104-Cell Holder for
10mm Water-Jacketed
4-Cell Holder
900620
imagesnameog_modelog_pricepriceMicro Cell Holder(Beam height: 15mm)9002408-Position Auto Cell Changer9003104-Cell Holder for
Milas Deuterium
Lamp
916633
imagesnameog_modelog_pricepriceMicro Cell Holder(Beam height: 15mm)9002408-Position Auto Cell Changer9003104-Cell Holder for
Halogen Lamp(Philips)
6V10W: 911634
imagesnameog_modelog_pricepriceMicro Cell Holder(Beam height: 15mm)9002408-Position Auto Cell Changer9003104-Cell Holder for
Halogen Lamp(Philips)
12V20W: 916634
imagesnameog_modelog_pricepriceMicro Cell Holder(Beam height: 15mm)9002408-Position Auto Cell Changer9003104-Cell Holder for
Halogen Lamp(Osram)
961634
imagesnameog_modelog_pricepriceMicro Cell Holder(Beam height: 15mm)9002408-Position Auto Cell Changer9003104-Cell Holder for
Self Masking Cont. Flowthrough G.Cell
(Beam height: 15mm)
5mm
916135
10mm
916136
20mm
916137
30mm
916138
Self Masking Cont. Flowthrough Q. Cell
(Beam height: 15mm)
5mm
916145
10mm
916146
20mm
916147
30mm
916148
imagesnameog_modelog_pricepriceMicro Cell Holder(Beam height: 15mm)9002408-Position Auto Cell Changer9003104-Cell Holder for
Thermal Printer
920910





Request Quote
Name*:
Email*:
I am *: Distributor End User Others
WhatsApp :
Product :
Subject :
Message :