Muffle Box Furnace BFX1C1 (BFMF-1200-5)
Standard Muffle Furnaces- Sea, Air, Door to Door Shipping
- 1 Year Warranty
- US & European Standards

Specifications
| Model | BFX1C1 |
| Working Temperature | 1200 °C |
| Volume | 5L |
| Inner Chamber Dimensions [mm] WxHxD | 150x150x225 |
| Product Outer Dimensions [mm] WxHxD | 446x618x620 |
| Net Weight [kg] | 43 |
| Power [W] | 2400 |
| Max. Current [A] | 9.1 |
| Electrical Connection | 1 Phase |
| Heating Element | Fe-Cr-Al |
| Thermocouple Type | K Type |
| Heating Element Placement | Embedded into brick walls |
| Inner Insulation Material | Insulating Fire Brick |
| Front Face Insulation Material | Insulating Fire Brick |
| Door Insulation Material | Ceramic Fibre Board |
| Housing Material | Steel Sheet |
| Housing Coating | Epoxy powder coating |
| Chimney | Standard |
| Heating Element Protection | Quartz Tube |
| Lockable Door Handle | Sidewards |
| Gross Dimensions [mm] WxHxD | 506x780x678 |
| Gross Weight [kg] | 57 |
| Software | BASIC B2 |
| Software based PID Control | YES |
| Display | 4 lines |
| Heating Program with | 4 steps |
| Custom Preset Program | 2 |
| Heating Rate °C/min. | 1-20 |
| Date & Time | YES |
| Auto Start at Certain Date | NO |
| Show Remaining Waiting Time | NO |
| Skip the Waiting Step | NO |
| Temperature Calibration via Menu (±10°C) | NO |
| Sound Warnings at Step Changes | YES |
| Sound Warning at the End of the Program | YES |
| Total Working Hour Counter | YES |
| Calculator for Average Working Temperature | YES |
| Instantaneous Energy Consumption Indicator | NO |
| Over Heating Cut Off | YES |
| Open Door Sensor | OPTIONAL |
| PC Connection Kit | OPTIONAL |
| Warranty Period | 2 Years |
| Note | * Only 5th memory supports 32 levels **Independent for each level |
Features
• Suitable for every kind of processes like ashing, sintering, preheating, melting, oxidizing.• User friendly operating menu in 4 line display for easy operation.
• Durable inside lining made of light insulating bricks.
• Accurate measuring and controlling the temperature using K and S Type thermocouples.
• ±1 °C control accuracy.
• Designed for minimal space requirements in the laboratory, thanks to the highly engineered insulation design.
• Dual shell housing for low outer surface temperature.
• Optional protective gas connection, door switch, second thermocouple for different adjustable purposes.
• Lift up and Sidewards opening door possibilities.
• Standard chimney with fan.
• Robust, durable and reliable.
• Ideal for all washing, burning and similar processes.
• Bottom, side and top walls and front facing insulations made of light firebrick.
• Lockable door handle.
• Optional Lift-up door.
Operating Manual
Download1. Introduction
2. Main Technical Parameters
3. Characteristics
4. Installation and operation
5. Attentions
6. Meter operation instruction
1. Introduction
This series of furnace are used for analyzing element in laboratories, mineral enterprises and science research institutes. It is also used in heating processing for the small size steel annealing and tempering.
2. Main Technical Parameters
Model | BFMF-1200-5 | |
Heating mode | Alloy wire heating in three sides left; right; top side. | |
Function | Temp. Range | 100-1200°C |
Temp. Resolution Ratio | 1°C | |
Temp. motion | ±1°C | |
Temp.Rising time to max temp | ≤30min | |
Structure | Chamber material | Ceramic fiber |
Outer shell | cold rolling steel electrostatic spraying exterior; B model: stainless steel | |
Insulation layer | Ceramic fiber | |
Heater | Alloy heating wire | |
Power rating | 3.0kW | |
Exhaust hole | φ30mm(chimney size 80*60mm) | |
Controller | Temp. control mode | domestic brand single controller |
Temp. setting mode | Touch button setting | |
Temp. display mode | Measuring temperature: LED upper row, setting temperature: the lower row | |
Timer | 0-9999min (with timing wait function) | |
Operation function | Fixed temperature operation, timing function, auto stop. | |
Additional function | Sensor deviation correction, Temperature overshoot self-tuning, Internal parameter locked, Power-off parameter memory | |
Sensor | Platinum-rhodium sensor | |
Safety device | Manual door security lock, over temperature sound-light alarm, door opening electrical outage, over-temperature protection,thermocouple failure | |
Specificati on | Inner Chamber size (W*L*H)(mm) | 200*300*120 |
Exterior size (W*L*H)(mm) | 530*785*640 | |
Packing size (W*L*H)(mm) | 660*875*770 | |
Volume | 7L | |
Current rating (50/60HZ) | AC220V/13.6A | |
NW/GW (kg) | 45/50 | |
optional type | LCD program temperature control device with USD date storage | |
3. Characteristics
All stainless steel glory hole to make sure its color will not change.
Imported double insulation ceramic inner chamber with stable performance.
Vacuum forming polycrystalline mullite fiber furnace hearth has characteristics of efficient insulation and three side heating of special alloy heating wire to provide optimum temperature uniformity.
The perfect combination of high precision micro-computer controller and accurate sensor has advantage of precise temperature.
Double-shell hollow thermal insulation and double ventilation duct with advantages of excellent ventilation, not hot shell and quick internal cooling.
The furnace with multiple safety protection measures, such as thermocouple failure, over door opening electrical outage, audio-visual alarm, etc.
4. Installation and operation
Open the package, check the furnace and make sure the whole set is complete. Place the furnace on smooth ground or table. Keeps the controller avoiding vibration.
Install the power switch at the original power line to control the whole power. To make sure the equipment operates safely, furnace and controller must be grounded reliably.
Connect the controller direction to the line and make sure it is correct. Then put through the power, turn on the power and set the temperature on the meter. It starts to heating when indicator light of the meter turns green. Adjust the power to reach the target temperature as it is needed, but make sure the voltage and electric current of the product will not surpass the rated power.

5. Attentions
Install the outer ground protection to ensure safety of machine and experiment; ensure power as the machine required. |
This equipment is forbid to use in inflammable and explosive, poisonous and strong corrosive experiments. |
Make sure horizontal installation. |
Non-professionals are not allowed to disassemble and repair this machine. |
Pay attention to the setting temperature when dealing with inflammable matters. |
Make sure dry the resin container, if the temperature is setting too high by accident, the container would be dissolved and then fall on the heater, which will cause fire. |

Overfilled of sample will lead to overheat of working room under part, which will dissolve the inflammable material and cause fire. |
While the machine is working, don't touch the device top, as well as observation window and exhaust port to keep away from high-temperature burns. |
Please do not open the door when the temperature more than 500°C! |
please use the temp.50°C less than the Max. temp. for long hours use! |
Read the instruction book before operation. |
6. Meter operation instruction
1) Model Single-stage Temperature Controller
1.1 Basic display status
When powered on, it shows the basic display status, upper window displays real process value (PV) while lower window displays the set value (SV). If the real value overruns measure range(thermocouple breaks for example), upper window will display "orAL" and the highest and lowest values, at this time, controller will automatically stop controlling the output.
In controller's face, basically there are 6~10 LED lights,OP1,AU1,AU2,RUN which respectively stand for output, first alarm, second alarm, and working condition.
1.2 Time programm setting:
In basal display status, if the parameter lock "Loc" isn't locked, we can set setpoint (SV) by pressing
,
or
. Press key to decrease the value,
key to increase the value, and
key to move to the digit expected to modify. Press
till it shows "t1", we can set time.
1.3 Working control
When power on, the controller is in stop status, you can press
for 2 seconds till the below window shows"run" to start controller's working. Press
for 2 seconds till it shows "stop" to stop the controller's working.
1.4 Preparation
If you don't want to count time when it's still in raising temperature, you need this preparation. When you start preparation function,controller won't alarm when it shows unnormal value
(HaAL& LdAL). At this time, programmer stops counting time until the value is normal.
1.5 AI artificial intelligence control and auto tuning:
When AI artificial intelligence control method is chosen , the PID parameters can be obtained by running auto-tuning. In basal display status, press
for 2 seconds, the "At" parameter will appear. Press
to change the value of "At" from "oFF" to "on", then press
to active the auto-tuning process. During auto tuning, the instrument executes on-off control. After 2-3 times of on-off action, the instrument will obtain the optimal control parameter value. If you want to escape from auto tuning status, press and hold the
key for about 2 seconds until the "At" parameter appear again. Change "At" from "on" to "oFF", press
to confirm, then the auto tuning process will be cancelled.

Note1 : If the setpoint is different, the parameters obtained from auto-tuning are possible different. So you'd better set setpoint to an often-used value or middle value first, and then start auto-tuning. Depending on the system, the auto-tuning time can be from several seconds to several hours.
Note2: Setting of CHYS may have influence on AT.. The lower value of CHYS the higher accuracy. But too low CHYS isn't advice, CHYS=2.0 is advice.
Note3: At the beginning after AT, the result maybe not table but it will get best result after a time.
Parameter Setting:
Note:All the internal parameter has been adjusted when factory test. Forbidden to modify them except Sensor Correction parameter.
In basal display status, press
and hold for about 2 seconds can access Field Parameter Table.Pressing
can go to the next parameter; pressing
,
or
can modify a parameter.Press and holdcan return to the preceding parameter. Press
(don't release) and then press
key simultaneously can escape from the parameter table. The instrument will escape automatically from the parameter table if no key is pressed within 30 seconds. Setting Loc=808 and then presscan access System Parameter Table.

Field parameter table (Pressand hold for 2 seconds to access)
Cod e | Name | Description | Factory value |
HIAL | High limit alarm | Alarm on when PV (Process Value) >HIA; alarm off when PV<HIA-AHY | 3000 |
LoA L | Lower limit alarm | Alarm on when PV (Process Value) <LoA; alarm off when PV>LoA-AHY | -999 |
HdA L | Deviationhigh alarm | AlarmonwhenPV-SV>HdA;alarmoffwhen PV-SV<HdA-AHY | 50 |
LdA L | Deviationlow alarm | AlarmonwhenPV-SV<LdA;alarmoffwhen PV-SV>HdA-AHY | -999 |
Loc | Parameter Lock | Loc=0: Allowed to modify parameters and do AT Loc=1: Allowed to modify parameters but cannot AT Loc=2: Allowed to modify parameters and AT Loc=4-255: NOT allowed to modify parameters ecept Loc. Loc=808, Set to 808 and press, allowed modify all parameters. | 0 |
AHY S | Hysteresis | Avoid wrong frequent alarm caused by wrong value setting | 2 |
AoP | Alarm Output assignment | AoP is to define the place of HIAL,LoAL,HdAL alarms like : Value 0~4.0 means never alarm, 3and4 mean alarm from AU1,AU2. E.g. AOP=403 means HIAL alarm from AU1, HdAL from AU2.LoAL no alarm | 0~4444 |
CrL | Control mode | onoF : On-off control, used in normal case APld: high precision control PID mode nPld: standard PID control | APId |
Srun | Running status | Run,normal running status,PRG light on Stop, stop status,below windo shows "stop",PRG light out Hold, keep current status, program stop counting time at this moment | stop |
Act | Dierect/reverse acting function | rE:Reverse acting.Increase in measured variable causes a decrease in the output,such as heating control. dr:Direct acting.Increase in measured variable causes an increase in the output,such as refrigerating control. rEbA:Reverse acting with low limit alarm and deviation low alarm blocking at the beginning of power on. drbA:Direct acting with high limit alarm and deviation high alarm blocking at the beginning of power on. | rE | ||||
P | Proportional band | Proportional band in PID with unit°C/F. Notes:normally use At to confirm P,I,D and Ctl .But can set known correct value. | 30 | ||||
I | Time of Integral | Time of integral in PID.No integral effect when I=0 unit is 1 second | 100 | ||||
d | Timeof Derivative | Time of derivative in PID.No derivative effect when d=0. Display unit is 0.1second | 50 | ||||
Ctl | Control period | Small value can improve control accuracy. For SSR output, generally 0.5 to 3.0 seconds. For Relay output, generally 15~40 seconds, because small value will cause the frequent On-Off of mechanical switch and shorten its service life. CtI is recommended to be 1/4 ~ 1/10 of derivative time. When control under on-off control,Ctl use as restart delay time affer off,for protect compressor application. | 2.0 or 20 | ||||
CHYS | Control Hysteresis | CHY is used for on-off control, if PV > SV, output turns off; PV<SV-CHYS, output turns on. | 2 | ||||
InP | Input specification | InP | Input spec | InP | Input spec | 1 | |
0 | K | 1 | S | ||||
2 | R | 3 | Spare | ||||
4 | E | 5 | J | ||||
6 | Spare | 7 | N | ||||
8-20 | Spare | 21 | Pt100 | ||||
dPt | Resolution | "0" means 1°Cor 1F, "0.0" means 0.1°C/F | 0 | ||||
Scb | Input Shift | Scb is used to make input shift to compensate the error produced by sensor or input signal. PV_after_compensation= PV_before_compensation + Scb. Note:normally set it as 0 | 0 | ||||
FILt | PV input filter | The value of FIL will determine the ability of filtering noise. If great interference exists, then you can increase parameter "FIL" gradually to make momentary fluctuation of measured value less than 2 to 5. When the instrument is being metrological verified, "FIL" s can be set to 0 or 1 to shorten the response time. | 1 | ||||
Fru | Power frequency and display unit | 50C --fequency 50Hz,display unit °C.50F-- fequency 50Hz,display unitF. 60C --fequency 50Hz,display unit °C.60F-- fequency 50Hz,display unitF. | 50C | ||||
OPH | Outputhighest limit | When PV<OEF,max limit 100% | 100 | ||||
OEF | OPH valid range | When PV<OEF,OUTP output highest limit is OPH, When PV>OEF,no limit ,100% output Note:if you want to avoid too quick temperature raising, and temperature is lower than 150C, only 30% is allowed for heating power, then you can set: OEF=150.0 °C, OPH=30% | 3200 |
AF | Senior function code | AF=A*1+B*2+E*16+G*64 A=0,HdAL and LdAL is for Hysteresis alarm;A=1,they are absolute alarm B=0,single lop alarm, B=1,Dual loops alarm E=0,HIAL ,LOAL are absolute highest alarm and howest alarm E=1,HIAL,LOALarehysteresishighestalarmand hysteresis lowest alarm G=0,sensor allow ,. G=1,not allow higher than highest alarm value Set it as 0 unless an expert tells you to change. | 0 |
SPL | Lower limit of SV | Minimum value of SV | 0 |
SPH | Upper limit of SV | Maximum value that SV allowed to be. When SPH=400,the SV range will 0~400°C. | 1200 |
SPr | Limit of temperature rising speed | If SPr is set as valid, when controller works, RUN light will shine if wrong or unormal speed occurs. | 0 |
PonP | Autorunning when power on | Cont, controller stop work StoP, when power on, it's in stop status. Run1, continue working dASt, if now alarm, then work, if alarm, stop working HoLd, (only for AI-518P),if accident short of electricity, stop work. | cont |
EP1~ EP8 | Senior function code | Can set 1~8 field parameter. If not need or less than 8, can set it as nonE. |


Press(∧)or(∨)keyboard to change the setting number, press(<)to change the number is more easy and fast.
At temperature self-tuning:
Press SEL 5 seconds, the display shows MAN, press SEL again till display the AT, you can see display OFF, please change it to ON by(∧)or(∨), press the SEL and the back keyboard and the machine doing the self-tuning.
The display shows AT, the AT will disappear when the self-tuning work stop, please do not turn off the power, if turn off the power, please reset again. Please make sure there is no sample in the machine when doing the AT work.
Press the SEL to modify the follow specification: 
Press the SEL 5 seconds to modify the follow specification:
Programmable Temperature setting specification

After setting, please press SEL to change the PROG specification to RUN and then works till the finish
END display.


7. Wiring Diagram
ⅰ. Model Single-stage Temperature Controller

8. Fault analysis
Phenomena | Causation | Treatment Method | |
No power | No Power Supply Switch broken Wire short or fuse broken | Check the power or change the plug socket Change the switch Check the wire or change the fuse | |
SV display OraL | Sensor broken | Change the sensor | |
Alarm or Over temperature light on | Machine body higher than the limited temperature, protect now! | The Temperature down to safety temperature and recover by itself (Inspect the reason or change the limited temperature) | |
Not work | Specification wrong changed | Change the specification | |
Temperature no rising | Controller broken Heating Element broken | Contact with the repair | |