Laboratory Vertical Autoclave BEO1E1
Vertical Autoclave, Standard- Sea, Air, Door to Door Shipping
- 1 Year Warranty
- US & European Standards



Specifications
Model | BEO1E1 |
Capacity (L) | 29 |
Dimensions (LxWxH) mm | 460x542x976 |
Chamber dimension (DiaxH) mm | Φ320x378 |
Rated power (W) | 2300 |
Basket size (pcs) | (Φ298x260)x1 |
Power requirement | 220V±10% 16A 50Hz/60Hz |
Sterilization temp. range | 105°C-135°C |
Temperature display accuracy | 0.1°C |
Working environment | 5°C~40°C Relative humidity <85% |
Chamber material | SUS304 stainless steel (316L as option) |
Sterilization time range | 1-6000 min |
Melting temp. range | 60°C-115°C |
Melting time | 1-6000 min |
Warming temp. | 45°C-79°C |
Warming time | 1-9999 min |
Appointment timer range | Auto start up appointment)0 ~ 15 days |
Controller | "SMART III" microcomputer controller |
Exhaust speed control | Fully automatic internal discharging with 6 levels choice |
Memory function | 60 program saved in system,999 cycles saved by USB |
Cooling way | Fast cooling fan |
Pressure gauge range | -0.1-0.5MPa |
Pressure valve set pressure | 0.29Mpa |
Vacuum pump | Pulse: 1-9, Vacuum ≤-80kpa, Leak rate ≤0.13kpa |
Safety device | Lid check, dry protection, over-temp/pressure, electric safety, cooling lock |
Features
Safety1. Nice look
The lid and bench corners are covered with insulation to avoid getting scald
2. Lid closing check
The machine can not start if the lid is not locking well by checking mechanically and electrically.
3. Interlock
Only when the temperature and pressure are safe inside, can the door be opened. If the door is not closed in place, it cannot start working
4. Triple protection for water shortage
The bottom of the sterilization chamber is equipped with three different dry burning protection devices: liquid expansion type, copper temperature sensing type, and electric ion type (water level sensor), to avoid misjudgment caused by a single method.
5. Double protection for over pressure
Mechanical pressure gauge and electric sensing system, once pressure is abnormal, the system will cut power, release the pressure and send out an alarm.
6. Auto troubleshooting
System will monitor the working status, and will cut the power, send out alarm, and report the error information once any abnormal situation is detected.
7. Safety test function
Regular testing of system security and safety protection measures is possible
8. Temperature monitor
Power cut and alarming sent, if there is temperature is too high or temperature rising is abnormal
9. Electrical production
Prevention for over current, short circuit and electricity leakage
10. Saturated steam monitoring
The system automatically monitors the purge out of cold air to ensure the pure steam
Intelligent
1. Calibration port
Offer temp. and pressure interface, together with the 3Q adapter joints, can insert max 15 sensors one time to do the calibration work
2. Saturated steam monitoring
The system automatically monitors the purge out of cold air to ensure the pure steam environment
3. Program memory storage system
Users can set their own program, and save it in the system.
4. Special software for drug packaging materials (option)
The product meets the 2020 Chinese Pharmacopoeia or EP10.2 standards
Accessories For Purchase
images | name | description |
![]() | Micro printer | To print temp. time and FO value |
Printing set:printer+digital
pressure sensor:can print temp.and pressure in data and flowchart way

pressure sensor:can print temp.and pressure in data and flowchart way




(3Q)adapter joint