Gradient PCR Thermal Cycler BFA1O2 (BTHC-602)
Gradient Pcr Instrument, Gradient Pcr Thermal Cycler- Sea, Air, Door to Door Shipping
- 1 Year Warranty
- US & European Standards

Specifications
Model | BFA1O2 |
Single step time | 1~59m59s (0 is forever) |
Temp. range | 4~99.9°C (constant temp.: 4°C) |
Sample capacity | 96x0.2ml / 384x0.04ml |
Max. heating rate | 4.5°C/s |
Max. cooling rate | 4°C/s |
Temp. uniformity | ±0.25°C |
Temp. accuracy | ±0.20°C |
Temp. display resolution | 0.1°C |
Temp. control method | Block/Tube |
Gradient temp. uniformity | ±0.3°C |
Gradient temp. accuracy | ±0.3°C |
Gradient temp. range | 30~99.9°C |
Gradient temp. difference range | 0.1~30°C |
Hot cover temp. range | 30~110°C |
Max. steps of the program | 30 |
Program max. cycle nu | 99 |
Time increment/decrement | -599~+599s |
Temp. increase/decrease | -9.9~+9.9°C |
Program pause function | Yes |
16°C Insulation | Forever |
LCD | 5 inch, 800x480 Pixel |
Program storage quantity | >100 |
Communication Interface | USB 2.0 |
Input power | 100~240V AC6.6~3.1A 50/60Hz |
Power | 600W |
Fuse | 250V 5A, Φ5x20 |
Dimensions | W.205xD.280xH.160mm |
Net weight | 4.3kgs |
Description
The gene amplification instrument is mainly used for gene amplification in scientific research, qualitative PCR gene amplification, fluorescence / enzyme immune endpoint quantitative DNA gene amplification, gene chip and other analytical applications of gene amplification, etc.Features
New and unique appearance, the interface operation is simple and convenient, compact size.The latest generation of semiconductor technology, excellent augmentation performance, effectively eliminate the edge effect of module heat conduction, the module temperature uniformity is excellent. Built-in multi-channel refrigeration film, several sensors are evenly distributed, the program temperature control is more precise.
5-inch TFT high-definition full-touch color screen, can quickly edit the required files, visual display of temperature curve, convenient and fast setting, accurate display of temperature curve and instrument running process status in real time.
The system has a built-in gradient calculator, which can easily obtain accurate annealing temperature for different experimental samples to optimize PCR reaction conditions.
User login, rights management, password protection, data security, administrators can clear users,large data storage, the maximum number of files that can be stored in the machine is greater than 100.
The ingenious elastic hot cover structure design, ADAPTS to the different height test tube, guarantees the best conditions for the test.
Real-time display of gradient temperature distribution, real-tmi e temperature display, more conducive to controlling the sampel temperature.
The hot lid temperature and working mode can be set, hot lid can be switched on and off, and test tube temperature control mode and module temperature control mode can be choose to meet more different experimental requirements.

One-click open button

96-well large sample table

Uniformity

Remove edge effect technique

5-inch display

Gradient Calculation