CO2 Incubator Water Jacketed AC220V/50Hz 1000W

Specifications

ModelBGI2E2
Electrical requirementAC220V/50Hz
Input power1000W
Heating powerWater Jacket
Temp. control rangeRT+5 - 50°C
Work environment temp+5 - 30°C
Temp. accuracy±0.1°C
CO₂ control range0 - 20%
CO₂ control accuracy±0.1% (IR sensor)
CO₂ restore time(Door open 30s, recovery to 5%) ≤ 3min
Temp. restore time(Door open 30s, recovery to 37°C) ≤ 8min
Related humidityNature vaporate > 95% (Can equip with related humidity digital display)
Volume240L
Chamber size WxDxH (mm)600x520x780
Overall size WxDxH (mm)754x760x1020
Standard shelves qty3 pcs
SterilizationUV sterilization + HEPA sterilization

Description

The water jacket CO₂ incubator is designed for a long time stable culture. The control temp. is stable and accurate, suitable for the microorganisms culture with a long cycle and does not need to open the door often.

Features

Intelligent touch screen controller:
Replace traditional button operation to touch screen interface.
It can display on the performance curve. You can check the temp., humidity (option) and CO₂ concentration three group curves changes at the same time.
And abnormal alarm and door open or close message.
When parameters are set, the controller will lock the screen automatically. It avoids unauthorized person wrong operation on the machine.
72 hours machine performance inquiry. It is convenient for user to check abnormal situation and track historical running information.
RS-485 communication port as options can be remote control on computer for monitoring the running and start or close the machine.
Intelligent touch screen controller: Replace traditional button operation to touch screen interface. It can display on the
Intelligent touch screen controller: Replace traditional button operation to touch screen interface. It can display on the
Intelligent touch screen controller: Replace traditional button operation to touch screen interface. It can display on the
Intelligent touch screen controller: Replace traditional button operation to touch screen interface. It can display on the

CO₂ concentration sensor:
You may need to open door frequently during experiment, Infrared sensor is the best choice under this circumstances. Our Infrared sensor is very sensitive to CO₂ concentration varies and it will not be affected by inside of incubator chamber conditions, measured accurately. It doesn't like traditional thermal probe that will be sensitive to chamber temp., and humidity that lead to incorrect CO₂ concentration data.
If open the door for 30s and close the door, within 3 min the CO₂ concentration can resume to the set value 5%. Even if there are many people use the same machine and frequently open and close door, the inside chamber can still maintain CO₂ concentration stable and uniform.

Temperature control and monitoring system:

A. Incubator temperature control system
PT100 temp. sensor keeps inside chamber temperature accurate. It can adjust the heating power according to the temp. differences between actual temp. in the chamber and set temp. to make sure temp. in the chamber is accurate. It can resume experiment temp. in 3 min after user open and close door to take samples.

B. Water jacket heating system
Water jacket heating method to ensure working chamber temperature is uniform, when it is power off, the chamber can maintain the temp. for a long time.

C. Door heating system
Outer door ring has heating function. The temperature of door ring will be a little bit higher than temp. in the chamber to prevent condensed water coming from the inner glass door. It facilitates observe the experiment process, also it can avoid the biological pollution possibility due to the condensed water from the inner glass door.

D. Over temp. protection system
It is an independent backup temp. control system besides the CO₂ incubator temp. control system. When the incubator temp. control system failed and caused temp. loss control, the chamber temp. reaches to the over temp. limited set value, over temp. protection system will cut down the heating and alarm audible with light.

Documentation and failure diagnostic display (Option):
All data can be stored through RS485 port, if full functions. User can read the diagnostic situation and data from computer at any time.

Pollution proof control:

A. Ultraviolet sterilization
The ultraviolet lamp is placed at the back top of the chamber. It can sterilize the chamber regularly. It kills chamber recycle air bacteria and float bacteria from water tray or slop water in the bottom, effectively prevent pollution during cell culture period.

B. HEPA efficient filters
The CO₂ gas quality is an important factor to judge cell culture. In the CO₂ Incubator, HEPA high efficient filters can filter bacteria and dust in the air. It eliminates cross contamination from outer air to incubator chamber and keep the chamber inside aseptic. Close the door for 5 min, inside air can fast resume to hundred grade clean. HEPA air filter is easy to disassemble without any special instruments.
B. HEPA efficient filters The CO₂ gas quality is an important factor to judge cell culture. In the CO₂ Incubator, HEPA high

C. Micro biological HEPA filter
CO₂ access port equips micro biological HEPA filter, it can filters diameter ≥0.3μm Particles like CO₂ gas, bacteria and dust, the efficient reaches to 99.99%.
C. Micro biological HEPA filter CO₂ access port equips micro biological HEPA filter, it can filters diameter ≥0.3μm

Cycle fan speed adjustable automatically
Cycle fan speed can be adjusted automatically. When chamber temp. is stable, the fan speed will be lower down, the speed will be adjusted to a suitable speed that the cell can grow with. It avoids the fast fan speed that evaporating the samples.

CO₂ inlet control system
We supply pressure release valve together with the equipment. It can control the pressure stable.
The system has pressure protection function. It prevents over pressure or low pressure to the pipes.

Safe Functions:
High and low temp. and over temp. alarm
Door temp. sensor failure alarm
CO₂ condensation too high or too low alarm
Door open too long alarm
Chamber sensor failure alarm
Over temp sensor failure alarm
Independent temp. limiter alarm