Air-jacketed Multi gas Incubator BFN1I1

Tri-gas Incubator
  • Sea, Air, Door to Door Shipping
  • 1 Year Warranty
  • US & European Standards



Air-jacketed Multi gas Incubator Direct heat & air jacket Pt1000

Specifications

ModelBFN1I1
Temp. Control MethodDirect heat & air jacket
Temp. Control sensorPt1000
Temp. Range (°C)Amb. +3 to 55°C
Temp. Accuracy (°C)±0.1
Recovery Time≤7 mins (After 30 sec. Door opening)
CO₂ control systemMicroprocessor PID
CO₂ range (% CO₂)0-20
CO₂ accuracy (% CO₂)±0.1 (at 37°C)
CO₂ sensorIR standard or TC optional
O₂ range (% O₂)1.0%-20% or 3.0%-85.0%
O₂ accuracy (% O₂)±0.2 (at 37°C)
O₂ sensorZirconium
Humidity range (% RH)≥90%±3%R
Interior Volume151 L
External Dimensions (mm) (WxDxH)637x768x869
Interior Dimensions (mm) (WxDxH)470x530x607
Net Weight75 kg
Standard Quantity of Shelves3
Maximum Quantity of Shelves10
Shelf Dimensions (mm) (WxD)423x445
Max. Load per Shelf (Kg)10
Available Electrical configuration220V±10% / 50Hz (standard)
Rated Power≤650VA±10%
Interior materialStainless steel, type 304

Description

Tri-gas incubator, providing precise temperature, CO2, O2 control as well as high humidity, is widely used in scientific research to grow and maintain cell cultures. Typical fields of application include tissue engineering, in vitro fertilization, neuroscience, cancer research and other mammalian cell research.

A. Stainless steel chamber with easy-to-clean coved corners reduces contamination-prone surface.
B. The turbulence-free chamber ventilation improves CO2, O2, humidity and temperature uniformity.
C. Easy-removable,replaceable shelves make chamber cleaning a rapid and efficient process.
D. Standard three inner glass doors minimize recovery time and the risk of contamination.
E. The design of water reservoir replacing water tray, allows rapid recovery of optimal humidity.
F. Water level alarm(audible and visible) alerts users when the water reservoir needs to be refilled.
G. Integrated electric siphon pump facilitates drainage operation.

Features

Contamination prevention:
90°C disinfection routine decontaminates the entire interior of the chamber while causes less damage to electronic components
In independent tests, a routine disinfection circle is proven to completely eliminate a variety of contaminants including mycoplasma
A completely smooth inner casing with rounded corner reduces the possibility of hidden contamination. Easy-removable, replaceable shelves make chamber cleaning a rapid and efficient process.
Contamination prevention: 90°C disinfection routine decontaminates the entire interior of the chamber while causes less
90° moist heat decontamination

Condensation control Air-jacketed Multi gas Incubator Direct heat & air jacket Pt1000
Condensation control

Temperature control:
Direct heating enables rapid temperature recovery while air jacket provides isolation against ambient temperature fluctuations
PT1000 temperature sensor ensures stable temperature control with little gradient and prompt temperature recovery without overheat
Three temperature control settings (main heater, outer door heater and overheat protection) minimize condensation and yield precise temperature uniformity.

CO2 control:
Drift free IR CO2 sensor responds extremely fast to gas concentration changes
Auto-zero runs automatically to recover the indicator to 'zero' every 24 hours
HEPA filter of CO2 inlet port can remove impurities and contaminants with efficiency 99.998% @ 0.2um
Standard CO2 cylinder auto changer alerts users and ensures continuous CO2 supply.
CO2 control: Drift free IR CO2 sensor responds extremely fast to gas concentration changes Auto-zero runs automatically to
AUTO START

Access port Air-jacketed Multi gas Incubator Direct heat & air jacket Pt1000
Access port

Gas Guard Set Air-jacketed Multi gas Incubator Direct heat & air jacket Pt1000
Gas Guard Set

O2 control:
Maintenance-free zirconium oxide sensor: long life, good linearity and high precision
Oxide sensor is calibrated automatically(auto-cal) and stays in the incubator during the 90°C decontamination routine
Well designed O2/N2 inlet module improves humidity stability in chamber.
O2 control: Maintenance-free zirconium oxide sensor: long life, good linearity and high precision Oxide sensor is calibrated

Constant humidity
Larger water surface area provided by water reservoir with inclined and rounded corners
A new water level alarm(audible and visible) alerts users when the water reservoir needs to be refilled.
Standard humidity sensor ensures a constant high level of humidity to prevent cultures from drying out.

User-friendly interface:
Microprocessor with soft-touch control panel for optimum operation
Large-size TFT-LCD display for temperature, CO2, O2 concentration and RH
Comprehensive visual and audio alarms for all parameters
Diagnostic interface provide comprehensive solutions to frequently encountered problems.
RS8232 port standard for communication and external instrument logging.
User-friendly interface: Microprocessor with soft-touch control panel for optimum operation Large-size TFT-LCD display for
Large-size TFT-LCD

Real-time monitoring system Air-jacketed Multi gas Incubator Direct heat & air jacket Pt1000
Real-time monitoring system




Request Quote
Name*:
Email*:
I am *: Distributor End User Others
WhatsApp :
Product :
Subject :
Message :