(21) items
Compare Selected (0)
Go
Thermal Cycler
Advanced

Thermal Cycler BFJ1T1

Thermal Cycler

Capacity : 16x0.2ml (4x4 layout)
Formats : 0.2ml single tube
Reaction Volume : 5-80μl
Temperature Range : 4-100°C
MAX. Ramp Rate : 5°C/s
Thermal Cycler
Advanced

Thermal Cycler BFJ1T2

Thermal Cycler

Capacity : 32x0.2ml (4x8 layout)
Formats : 0.2ml single tube, 8 strip
Reaction Volume : 5-80μl
Temperature Range : 4-100°C
MAX. Ramp Rate : 5°C/s
Thermal Cycler
Premium

Thermal Cycler BFJ1R1 (BTHC-106)

Thermal Cycler

Capacity : 96x0.2ml
Formats : 0.1/0.2ml tube, 8 strips, 12 strips, Half skirt 96 wells plate, No skirt 96 wells plate
Reaction Volume : 5-120μl
Temperature Range : 0-105°C
MAX. Ramp Rate : 4.5°C/s
Thermal Cycler
Premium

Thermal Cycler BFJ1R2

Thermal Cycler

Capacity : 96x0.2ml + 77x0.5ml
Formats : 0.1/0.2/0.5ml, 8 strips, 12 strips, Half skirt 96 wells plate, No skirt 96 wells plate
Reaction Volume : 5-80μl, 5-120μl
Temperature Range : 0-105°C
MAX. Ramp Rate : 4.5°C/s
Thermal Cycler
Premium

Thermal Cycler BFJ1R3

Thermal Cycler

Capacity : 60x0.5ml
Formats : 0.5ml tube
Reaction Volume : 5-200μl
Temperature Range : 0-105°C
MAX. Ramp Rate : 4.5°C/s
Thermal Cycler
Premium

Thermal Cycler BFJ1R4

Thermal Cycler

Capacity : 384 well
Formats : 384 well plate
Reaction Volume : 5-30μl
Temperature Range : 0-105°C
MAX. Ramp Rate : 4.5°C/s
Thermal Cycler
Premium

Thermal Cycler BFJ1Q1 (BTHC-108)

Thermal Cycler

Capacity : 96x0.2ml
Formats : 0.1/0.2ml tube, 8 strips, 12 strips, Half skirt 96 wells plate, No skirt 96 wells plate
Reaction Volume : 5-120μl
Temperature Range : 0-105°C
MAX. Ramp Rate : 5°C/s
Thermal Cycler
Premium

Thermal Cycler BFJ1S1

In-situ Thermal Cycler

Capacity : 120x80mm
Temperature Range : 0-105°C
MAX. Ramp Rate : 4°C/s
Uniformity : ≤±0.2°C
Accuracy : ≤±0.1°C
Thermal Cycler
Premium

Thermal Cycler BFJ1Q2 (BTHC-117)

Thermal Cycler

Capacity : Double 48x0.2ml
Formats : 0.1/0.2ml tube, 8 strips
Reaction Volume : 5-120μl
Temperature Range : 0-105°C
MAX. Ramp Rate : 5°C/s
Thermal Cycler
Premium

Thermal Cycler BFJ1Q3

Thermal Cycler

Capacity : 48x0.2ml + 30x0.5ml
Formats : 0.1/0.2ml tube, 8 strips, 0.5ml tube
Reaction Volume : Left block: 5-120μl, Right block: 5-200μl
Temperature Range : 0-105°C
MAX. Ramp Rate : 5°C/s
Thermal Cycler
Premium

Thermal Cycler BFJ1P1 (BTHC-109)

Triple Block Thermal Cycler, Triple Block Thermal Cycler (general)

Capacity : 3x(32x0.2ml)
Formats : 0.1/0.2ml, 8 strips
Reaction Volume : 5-120μl
Temperature Range : 0-105°C
MAX. Ramp Rate : 5°C/s
Thermal Cycler
Premium

Thermal Cycler BFJ1P2 (BTHC-110)

Triple Block Thermal Cycler, Triple Block Thermal Cycler (gradient)

Capacity : 3x(32x0.2ml)
Formats : 0.1/0.2ml, 8 strips
Reaction Volume : 5-120μl
Temperature Range : 0-105°C
MAX. Ramp Rate : 5°C/s
Thermal Cycler
Elite

Thermal Cycler BFJ1U1

Thermal Cycler

Capacity : 96x0.1/0.2ml
Formats : Full 96 wells plate
Reaction Volume : 10-80μl
Temp. Range : 0-100°C
Max. Ramp Rate : 5°C/s
Thermal Cycler
Elite

Thermal Cycler BFN1D1

Thermal Cycler

Type : Standard edition
Sample holder replacement : Support
Independent operation of sample holders : Support
Electromagnetic control lock : Support
Sample holder specifications : 32 wells*0.2ml*3
Thermal Cycler
Elite

Thermal Cycler BFN1D2

Thermal Cycler

Type : Performance edition
Sample holder replacement : Support
Independent operation of sample holders : Support
Electromagnetic control lock : Support
Sample holder specifications : 32 wells*0.2ml*3
Thermal Cycler

Thermal Cycler BFA1M1

Gene Amplification Instrument, Gene Cycler

U Disk function : Unlimited downloads on USB flash drive, instrument supports import and export
Types of consumables : 0.2ml single tube, 8-Tube Strips
Communication Interface : 1*LAN 1*RS232 2*USB
96 well plate : 96 well plate (excluding Full skirt)
Wireless function : Supports WIFI connection
Thermal Cycler

Thermal Cycler BFA1M2

Gene Amplification Instrument, Gene Cycler

Sample capacity : 384x0.04ml
Temperature Uniformity : ≤±0.5°C
Types of consumables : 384-well PCR microplate
Temp. difference range : 1°C~30°C
Gradient temp. point distribution : 1~24
Thermal Cycler

Thermal Cycler BFA1M3

Gene Amplification Instrument, Intelligent Dual-slot Gene Cycler

Sample capacity : 32x0.2ml (A slot) + 64x0.2ml (B slot)
Types of consumables : 0.2ml single tube, 8-connected tube
Temp. difference range : 1°C~20°C
Gradient temp. point distribution : A~H
Net weight : 11.5kg
Thermal Cycler

Thermal Cycler BFA1M4

Gene Amplification Instrument, Intelligent Three-slot Gene Thermal Cycler

Sample capacity : 3x32x0.2ml
Types of consumables : 0.2ml single tube, 8-Tube Strips
Temp. difference range : 1°C~20°C
Gradient temp. point distribution : A~H
Net weight : 11kg
Thermal Cycler

Thermal Cycler BFN1E1

Thermal Cycler

Sample holder specifications : 96x(0.2ml)(A);54x0.5ml(B);96x0.2ml+77x0.5ml(C);384 well(D)
Sample holder replacement : Support
Temperature control method : Imported high-performance thermoelectric refrigeration
Temperature range : 0-99.9°C
Maximum heating rate : ≥5°C/s
Thermal Cycler

Thermal Cycler BFN1E2

Thermal Cycler

Sample holder specifications : 96x(0.2ml)+77x0.5ml(C);384 well(D)
Sample holder replacement : Support
Temperature control method : Imported high-performance thermoelectric refrigeration
Temperature range : 0-99.9°C
Maximum heating rate : ≥5°C/s