| pH: | |
| Range | - 2.00 to 20.00 pH |
| Resolution | 0.1, 0.01 pH |
| Accuracy | ± 0.01 pH |
| Calibration Points | Up to 5 |
| Standard Customization | Yes |
| Standard Recognition | NIST, GB and DIN buffers |
| mV: | |
| Range | - 2000.00 to 2000.00 mV |
| Resolution | 0.1 |
| Accuracy | ± 0.3 mV or ± 0.1 % |
| pX: | |
| Range | - 2.00 to 20.00 |
| Resolution | 0.1, 0.01 pX |
| Accuracy | ± 0.02 pX |
| Calibration Points | Up to 5 |
| ISE: | |
| Range | 1E-9 to 9.999E9 |
| Unit | mol/L, mmol/L, g/L, mg/L, μg/L, ppm |
| Resolution | Up to 4 significant digits |
| Accuracy | ± 0.5 % |
| Calibration Points | Up to 5 |
| Conductivity: | |
| Range | 0.000 μS/cm to 1000 mS/cm |
| Resolution | 0.001 μS/cm minimum; changed with range |
| Accuracy | ± 1.0 % FS |
| Reference Temperature | 20, 25 °C |
| Calibration Points | Up to 3 |
| Standard Recognition | 84 μS/cm, 1413 μS/cm; 12.88 mS/cm |
| Resistivity: | |
| Range | 5.00 Ωcm ~20.00 MΩcm |
| Resolution | 0.01 Ωcm minimum; |
| Accuracy | ± 1.0 % FS |
| TDS: | |
| Range | 0.00 mg/L ~300 g/L |
| Resolution | 0.01 mg/L minimum; changed with range |
| Accuracy | ± 1.0 % |
| Salinity: | |
| Range | (0.00 ~8.00) % |
| Resolution | 0.01 % |
| Accuracy | ± 0.2 % |
| Dissolved Oxygen Concentration: | |
| Sensor Type | Polarographic |
| Range | 0.00 to 50.00 mg/L |
| Resolution | 0.01 mg/L |
| Accuracy | ± 0.3 mg/L |
| Calibration Points | Air-saturated water or zero point |
| Barometric Compensation | Yes |
| Manual Salinity Factor Correction | Yes |
| Saturation: | |
| Resolution | 0.10 % |
| Accuracy | ± 10.0 % |
| Temperature: | |
| Range | - 5 to 110 °C, 23 to 230 °F |
| Unit | °C, °F |
| Resolution | 0.1 |
| Relative Accuracy | ± 0.2 |
| Measurement: | |
| Reading Mode | AutoRead( Fast, Medium, Slow), Timed, Continuous |
| Reading Prompts | Reading, Stable, Locked |
| Temp. Compensation | ATC, MTC |
| Data Management: | |
| Data Storage | 1000 results each |
| GLP Features | Yes |
| Inputs: | |
| pH Electrode | BNC(Q9) |
| Temp./DO Probe | 4-pin aviation connector |
| Temp./EC. Probe | 5-pin aviation connector |
| Outputs: | |
| USB | USB 2.0 flash memory device, PC,scanner |
| Display Options: | |
| Backlight | Yes |
| Auto Shutdown | 300, 600, 1200, 1800, 3600 sec, off |
| IP Rating | IP65 |
| Yes | General: Power |
| General: | |
| Dimensions | 90x255x40 mm |
| Weight | 500 g(1.1 lb) |