Biological Safety Cabinet Class II BCBS-306
Biolab Biological Safety Cabinet Class II Series is engineered specifically for laboratory operations that require user and product protection. Operates with a negative air pressure for personnel protection and HEPA filtered laminar airflow for product protection. Suitable for microbiological and research applications that do not involve radioactive substances and toxic contaminants.
- Stainless Steel 304 table for operation
- Digital LCD display for easy monitoring of all parameters
- Emission of 253.7 nm for highly efficient decontamination
- Motored front window with timer function
Specification
Features
ApplicationsAccessories Optional Accessories
Type | Class II, Type A2 |
Filter | HEPA Filter Effeiciency - 99.999% efficiency at 0.3 µm. Filter life Indicator HEPA Filter – 2
Filter Guard Type - Aluminum alloy frame , glass filter paper |
Airflow Volume (Inflow) | 649 m3 / h (382cfm) |
Airflow Volume (Down flow) | 64%: 1190 m3 / h (700 cfm) |
Exhaust | Airflow Volume Exhaust: 36%: 669 m3/h (394 cfm) |
Minimum Face Velocity | 75 linear feet per minute (lfpm) |
Inflow Velocity | 0.53±0.025m/s |
Down Flow Velocity | 0.35±0.025m/s |
UV Lamp | 40Wx1 |
Illumination | ≥1000 lux |
Work Surface Height | 750 mm |
Tested Opening | 200 mm |
Max Opening | 550 mm |
Internal Size (WxDxH) | 1700x600x660 mm |
External Size (WxDxH) | 1873x775x2295 mm |
Package Size (WxDxH) | 2020x1080x1900 mm |
Caster | None |
Front Window | Motorized. Two layer laminated toughened glass≥5 mm, Anti UV |
Main Body Material | Chamber Material – Cold-rolled steel coated with anti-bacteria powder coating |
Waterproof Socket | Two, Total load of two sockets: 500W |
Standard Accessory | Water tapx1, Gas tapx1 |
Noise | NSF 49≤61 dB/EN 12469≤58 dB |
Gross Weight | 363 kg |
Consumption | 500 W
Ground Resistance:≤0.10Ω |
Power Supply | AC220V/110V, 50Hz/60HZ, 9A, BTU/Hr: 1689 |
- Stainless Steel 304 table for operation
- Digital LCD display for easy monitoring of all parameters
- Emission of 253.7 nm for highly efficient decontamination
- Motored front window with timer function
- Two-layered marinated toughened glass (≥5mm) motorized front window
- Negative air pressure provides personnel protection by constant movement of air in working area
- Remote control operation including front sash movement and fan speed control
- Foot switch to adjust the height of the front window
- Centrifugal fan speed adjustable: H14 HEPA filter
- Collecting tank (4000 ml) collects spatters of working area without any leakage
- Intrinsic sterilization is achieved after activating cabinet for 30 min via UV timing
- Air drawn into the cabinet through air grill
- Filter Life Indicator: Pressure value displayed to show life utility of main filter
- Low noise and high energy efficiency for operational cost savings
- Audio and visual alarm for filter replacement, front window over height and abnormal airflow
Cell culturing, Genetics, Microbiological, Research, Cell Biology, Molecular Biology, Plant, Laboratory
Accessory Code | Name | Description |
BX-58522 | Fluorescent Lamp | |
BX-58534 | UV Lampx2 | |
BX-58546 | Base Stand | |
BX-58558 | Remote Control | |
BX-58582 | Drain Valve | |
BX-58594 | Waterproof Sockets | |
BX-58606 | Stainless Steel water & Gas Taps | |
Accessory Code | Name | Description | External Dimension | Package Size (mm) |
BX-58061 | Infrared Sterilizer | | 150x95x210 mm | |
BX-58073 | Airflow Tester | | | |
BX-58085 | Formalin Fumigation Sterilizer | | | 300x200x160 mm |
BX-58097 | Ammonium Hydrogen Carbonate Neutralizer | | | 300x200x160 mm |
BX-58109 | Armrest | | | |
BX-58121 | Laboratory Chair | | | |
BX-58133 | Dust Particle Counter | | | |
BX-58145 | Digital Sound Level Meter | | | |
BX-58157 | Illumination Meter | | | |
BX-58169 | Air Flow Anemometer | | | |
BX-58181 | Protective Garment | | | |
BX-58193 | Protective Gloves | | | |