Spark-Free Laboratory Refrigerator BLAR-414
- Sea, Air, Door to Door Shipping
- 1 Year Warranty
- US & European Standards
Laboratory refrigerators supplied with digital controller, glass door, alarm system to meet the demanding requirements of laboratory research. These refrigerator has temperature ranging from +2°C to +8°C and all models are combined with two exact sensors and auto defrost.
- Safety door lock and controller setting password to prevent unauthorized access
- Build-in back-up battery to display temperature and to operate audible and visual alarm system for up to 8 hours without AC power
- Auto on/off cooling fan to prevent cold air from leaking out when the door is opening
- Visual and audible alarm system: High/low temperature, power failure, sensor failure, door ajar
|
|
Instant Quote |
Specification
Features
Applications
| Capacity | 416 L |
| Temperature Range | 2~8°C |
| Ambient temperature | 10~32°C |
| Refrigerant | R290 |
| Noise | 50 db |
| Sensor Type | NTC |
| Defrost | Auto |
| Cooling method | Forced Air Cooling System |
| Shelf/drawer | Shelves/5 |
| Temperature controller | Microprocessor |
| Display | Digital display |
| Inside material | 304SS |
| Outside material | Color sprayed steel |
| Insulation | PURF |
| Interior size (WxDxH) | 685x429x1380 mm |
| Exterior size (WxDxH) | 800x552x1940 mm |
| Package size (WxDxH) | 890x655x2100 mm |
| Weight | 120/133 |
| Alarms | High/low temperature, Power failure, Thermostat failure, Door ajar, Power failure backup system |
| Input/Average Power | 2.37 kWh/24h |
| Current | 1.3A |
| Power | 240 W |
| Power Supply | 220 V 50 Hz |
- Safety door lock and controller setting password to prevent unauthorized access
- Build-in back-up battery to display temperature and to operate audible and visual alarm system for up to 8 hours without AC power
- Auto on/off cooling fan to prevent cold air from leaking out when the door is opening
- Visual and audible alarm system: High/low temperature, power failure, sensor failure, door ajar
- Power failure protection: turn on delay of the cooling system after power failure
- Controller error protection: the cooling system will remember the normal working cycle and keep working depending on this memory when controller or two sensor failed
- Keyboard lock, password protection to avoid set parameter randomly
- Accurate temperature controller, ensure the inside temperature within 2~8°C and accuracy 0.1 °C
- Specially designed forced-air cooling system, ensure frost-free cabinet and good temperature uniformity
- Suggested ambient temperature: 10~32°C
- Color spray steel plate inner chamber for friendly using and easy cleaning
- Wide available voltage range: 187V~242V
- 4 casters 2 with stopper and 2 adjustable feet for easy moving and fixation
- 5 adjustable steel wire shelves for easy storing
- 1 Standard test hole for convenient installation of temperature recorder
- Special designed service-free drainage system, ensure no water in the cabinet
- Auto on/off LED light with manual switch on control panel
Industry, Cosmetic, Pharmaceutical, Electronics, Laboratory, Medical, Research